The panels are rarely the leak
A module is a sealed laminate with a frame. Unless it is physically broken, it does not pass water. What passes water is the penetration where a mount or a flashing meets the roof, or the sealant around it, or a roof detail that was already marginal and now has hardware in it.
That distinction decides who fixes it. A roofer owns the roof surface and the flashing. A solar contractor owns the array. Many leaks need both, and the sequencing is where projects go wrong.
How a leak is actually located
- Note when it appears: during wind-driven rain, only in heavy storms, or after any rain at all. That pattern narrows the source.
- Map the interior stain against the roof above it, allowing for the fact that water travels along framing before it shows.
- Look for staining, rust, or debris dams at the penetrations, and at the low side of the array.
- Check whether the leak started after a roof replacement, a storm, or any work on the roof.
- Ask for a water test rather than a guess. A controlled spray from the roof isolates the source instead of re-sealing everything.
Who does what
If the leak is under the array, the panels have to come off that section before a roofer can work on it. That is why a leak near an array often becomes a removal and reinstallation project, and why the order is roof first, array second.
The split that decides your project sequence.
| Party | Owns |
|---|---|
| Roofer | The roof surface, the deck, underlayment, and roof-side flashing |
| Solar contractor | Removing and reinstalling the array, and the solar-side attachments |
| Both, sequenced | Anything where the array sits over the leak area, because the panels come off before the roof is repaired |
Sealant is maintenance, not a permanent fix
Sealant around a penetration is a wear item. It moves with the roof, it is exposed to sun and rain, and it eventually loses adhesion. A leak that appears at year eight on a system that was sealed at year one is telling you the sealant reached the end of its service life.
The durable repair is mechanical flashing that sheds water, with sealant as a secondary measure. If a proposal is only fresh sealant over old sealant, ask what happens at the next failure.
- Ask whether the repair is a new flashing or new sealant over old.
- Ask what material the flashing is and whether it is compatible with the roof type.
- Ask for photographs of the repair before the array goes back on, because after that nobody can see it.
After the repair
- Confirm the interior has dried and monitor the stain through the next heavy rain.
- Get the repair documented with photos, including the flashing detail before reinstallation.
- Keep the roof and solar paperwork together, because a future leak claim will need both.
- If the array was removed and reinstalled, confirm the attachments were replaced and permitted as required.