Work from the outside in
A solar system has a small number of places where production can be interrupted. Checking them in physical order, from the meter toward the roof, means you stop at the first break instead of guessing at the most expensive one.
Each step eliminates a whole category of cause.
| Order | What to check | If it is the cause |
|---|---|---|
| 1 | Utility service and meter status | Utility-side outage or a disconnected interconnection |
| 2 | AC disconnect at the wall | Someone turned it off, often during other work |
| 3 | Solar breaker in the main panel | Tripped breaker, sometimes from a surge |
| 4 | Inverter display or indicator lights | Inverter fault, which the display usually names |
| 5 | Monitoring platform for device-level status | Array-side or communications fault |
The first three checks are homeowner-safe
- Confirm the home has utility power at all. A whole-home outage looks identical to a solar outage in an app.
- Find the AC disconnect, usually a labelled switch near the meter or the inverter. Note whether it is on.
- Look at the solar breaker in the main panel. A tripped breaker sits between on and off rather than fully to one side.
- Do not reset a breaker more than once. A breaker that trips again is reporting a fault, not a nuisance.
Read the inverter before you call
Most inverters show a status code or a light pattern that names the fault. Photograph it. That single image shortens the visit and sometimes avoids it, because the provider can arrive with the right part.
A dark inverter with utility power present is different from an inverter showing a fault code. The first points at supply or the unit itself; the second tells you what the unit thinks is wrong.
Shapes of inverter evidence, and what each implies.
| Evidence | Implies | Next step |
|---|---|---|
| No lights, no display, AC present | Supply-side or unit failure | Licensed diagnostic |
| Fault code on display | Named fault, often specific | Record the code, then book |
| Normal display, zero production | Array-side or measurement issue | Compare device-level data |
| Normal display, production normal | Monitoring or billing question | Recheck the app and the bill |
When the inverter is fine and the array is not
If the inverter reports a healthy DC input but no output, the problem is on the supply or grid side. If it reports low or zero DC input on a sunny day, the array side is implicated: a string fault, a failed device, an open connection, or a ground fault.
Those conditions are diagnosed with a meter at the array. They are not homeowner checks, because the test points are energised and often on the roof.
What to send so the visit is short
- Photograph the inverter display, the AC disconnect, and the main panel breaker positions.
- Note the date and time production stopped, and whether anything happened that day.
- Confirm whether the utility had an outage or a meter change.
- Send the equipment brand, model, and system age.
- Attach the monitoring screenshot showing the last producing day.